Adaptive natural ventilation for sustainable green campus buildings in the humid tropics: A stochastic approach at Telkom University office building in Bandung, Indonesia
Main Article Content
Abstract
Telkom University Bandung, as one of the top-ranked green campuses in Indonesia, strives to meet the assessment criteria in campus sustainability instruments such as the UI GreenMetric World University Rankings. As energy and climate change constitute one of the most heavily weighted categories in this metric, efforts to save energy and adapt to climate change are essential. In tropical campuses like Telkom University, space cooling dominates operational energy use, and reliance on air conditioning can undermine both energy performance and indoor environmental quality. This study proposes a proactive and autonomous natural ventilation strategy for tropical campus buildings that combines low-cost indoor climate sensing with a mean-reverting stochastic Ornstein–Uhlenbeck (OU) model. The stochastic OU model forecasts the Predicted Mean Vote (PMV) in a building located in a tropical climate 15–30 minutes ahead. The framework was validated using sensor data from an office building at Telkom University in November 2025. The OU model tracked the observed thermal dynamics with high accuracy and generated stable response signals that opened windows during favorable cooling periods and closed them during periods of peak heat. This experiment on adaptive natural ventilation for cooling building indoor temperatures offers the Telkom University campus a scalable pathway to reduce cooling energy demand. This experiment also has the potential to strengthen Telkom University’s performance in the UI GreenMetrics World University Rankings.
Article Details
Section

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
How to Cite
References
Alfata, M. N. F., Nugroho, A. M., & Ekasiwi, S. N. (2014). Kenyamanan termal pada ruang iklim di dua daerah dengan karakteristik iklim yang berbeda, studi kasus: Malang dan Surabaya. Jurnal Permukiman, 9(1), 28–40. https://doi.org/10.31815/jp.2014.9.28-40
Ali, A. M., Razlan, Z. M., Jamal, Z. A. Z., Kohlhof, K., Rahim, N. A., & Shukor, S. A. A. (2019). IoT-based smart air conditioning control for thermal comfort. 2019 IEEE International Conference on Automatic Control and Intelligent Systems (I2CACIS, 289–294. https://doi.org/10.1109/I2CACIS.2019.8825079
Alshuwaikhat, H. M., & Abubakar, I. (2008). An integrated approach to achieving campus sustainability: assessment of the current campus environmental management practices. Journal of Cleaner Production, 16(16), 1777–1785. https://doi.org/10.1016/j.jclepro.2007.12.002
Balbis-Morejón, M., Amaris-Castilla, C., Rey-Hernández, J. M., Rey-Martínez, F. J., Velasco-Gómez, E., & San José-Alonso, J. F. (2020). Experimental study and analysis of thermal comfort in a university campus building in tropical climate. Sustainability, 12(21), 8886. https://doi.org/10.3390/su12218886
Cândido, C., De Dear, R., Lamberts, R., & Bittencourt, L. (2010). Cooling exposure in hot humid climates: are occupants “addicted”? Architectural Science Review, 53(1), 59–64. https://doi.org/10.3763/asre.2009.0100
Chaudhuri, T., Soh, Y. C., Li, H., & Xie, L. (2017). Machine learning based prediction of thermal comfort in buildings of equatorial Singapore. Proceedings of 2017 IEEE International Conference on Smart Grid and Smart Cities, 72–77. https://doi.org/10.1109/ICSGSC.2017.8038552
Cheung, T., Schiavon, S., Parkinson, T., Li, P., & Brager, G. (2019). Analysis of the accuracy on PMV – PPD model using the ASHRAE Global Thermal Comfort Database II. Building and Environment, 153, 205–217. https://doi.org/10.1016/j.buildenv.2019.01.055
de Dear, R. J., Leow, K. G., & Foo, S. C. (1991). Thermal comfort in the humid tropics: Field experiments in air conditioned and naturally ventilated buildings in Singapore. International Journal of Biometeorology, 34(4), 259–265. https://doi.org/10.1007/BF01041840
Dyvia, H. A., & Arif, C. (2021). Analysis of thermal comfort with predicted mean vote (PMV) index using artificial neural network. IOP Conference Series: Earth and Environmental Science, 622(1), 12019. https://doi.org/10.1088/1755-1315/622/1/012019Espejel-Blanco, D. F., Camas-Anzueto, J. L., Hoyo-Montaño, J. A., Valencia-Palomo, G., Hernández-De-León, H. R., & García-Barrientos, A. (2022). HVAC Control System Using Predicted Mean Vote Index for Energy Savings in Buildings. Buildings, 12(1), 38. https://doi.org/10.3390/buildings12010038
Fadhila, N. S., Alkadri, M. F., & Dewi, O. C. (2024). Bio-cooling façade in tropical climate. Sustinere: Journal of Environment and Sustainability, 8(2). https://doi.org/10.22515/sustinere.jes.v8i2.400
Fanger, P. O. (1970). Thermal Comfort: Analysis and Applications in Environmental Engineering. Danish Technical Press.
Farliana, N., Hardianto, H., Rusdarti, R., & Sakitri, W. (2024). Sustainability consciousness in higher education: Construction of three-dimensional sustainability and role of locus of control. Sustinere: Journal of Environment and Sustainability, 8(1), 80–90. https://doi.org/10.22515/sustinere.jes.v8i1.374
Feriadi, H., & Wong, N. H. (2004). Thermal comfort for naturally ventilated houses in Indonesia. Energy and Buildings, 36(7), 614–626. https://doi.org/10.1016/j.enbuild.2004.01.011
Gallardo, A., Beltrán, R., Lobato-Cordero, A., Gaona, G., & Palme, M. (2016). Evaluating thermal comfort in a naturally conditioned office in a temperate climate zone. Buildings, 6(3), 27. https://doi.org/10.3390/buildings6030027
Gan, V. J. L., Luo, H., Deng, M., Kwok, H. L., & Tan, Y. (2021). BIM and data-driven predictive analysis of optimum thermal comfort for indoor environment. Sensors, 21(13), 4401. https://doi.org/10.3390/s21134401
Huang, M., & Liao, Y. (2022). Development of an indoor environment evaluation model for heating, ventilation and air-conditioning control system of office buildings in subtropical region considering indoor health and thermal comfort. Indoor and Built Environment, 31(3), 807–819. https://doi.org/10.1177/1420326X21103555
Indraganti, M., Ooka, R., & Rijal, H. B. (2014). Adaptive model of thermal comfort for offices in hot and humid climates of India. Building and Environment, 74, 39–53. https://doi.org/10.1016/j.buildenv.2014.01.002
International Organization for Standardization. (2005). Ergonomics of the thermal environment—Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices.
Iqbal, M., Wahid, A., & Rosady. (2024). Kenyamanan termal pada bangunan berventilasi alami di iklim tropis. Nature: National Academic Journal of Architecture, 11(2), 123–135. https://doi.org/10.24252/nature.v11i2a3
Karaiskos, P., Alamaniotis, M., & Martinez-Molina, A. (2024). Examining the impact of natural ventilation versus heat recovery ventilation systems on indoor air quality: A tiny house case study. Buildings, 14(6), 1802. https://doi.org/10.3390/buildings14061802
Karyono, T. H. (2008). Bandung Thermal Comfort Study: Assessing the applicability of an adaptive model in Indonesia. Architectural Science Review, 51(1), 60–65. https://doi.org/10.3763/asre.2008.5108
Karyono, T. H. (2015). Predicting comfort temperature in Indonesia, an initial step to reduce cooling energy consumption. Buildings, 5(3), 802–813. https://doi.org/10.3390/buildings5030802
Karyono, T. H. (2018). Thermal Comfort in Indonesia. In T. Kubota, H. B. Rijal, & H. Takaguchi (Eds.), Sustainable Houses and Living in the Hot-Humid Climates of Asia (pp. 115–121). Springer Singapore. https://doi.org/10.1007/978-981-10-8465-2_11
Koebel, M. M., Rigacci, L. C., & Wernery, R. (2017). Energy in buildings—Policy, materials and solutions. MRS Energy & Sustainability, 4, 12. https://doi.org/10.1557/mre.2017.14
Lamsal, P., Rijal, H. B., & Bajracharya, S. B. (2023). A review on adaptive thermal comfort of office building for energy-saving building design. Energies, 16(4), 1524. https://doi.org/10.3390/en16031524
Laouadi, A. (2022). A new general formulation for the PMV thermal comfort index. Buildings, 12(10), 1572. https://doi.org/10.3390/buildings12101572
Lozano, R., Ceulemans, K., Alonso-Almeida, M., Huisingh, D., Lozano, F. J., Waas, T., Lambrechts, W., Lukman, R., & Hugé, J. (2015). A review of commitment and implementation of sustainable development in higher education: results from a worldwide survey. Journal of Cleaner Production, 108, 1–18. https://doi.org/10.1016/j.jclepro.2014.09.048
Mendell, M. J. (2007). Indoor residential chemical emissions as risk factors for respiratory and allergic effects in children: a review. Indoor Air, 17(4), 259–277. https://doi.org/10.1111/j.1600-0668.2007.00478.x
Muhammad, A. H., Taki, A., & Khattak, S. H. (2025). Assessing thermal comfort in green and conventional office buildings in hot climates. Sustainability, 17(15), 7078. https://doi.org/10.3390/su17157078
Nnaji, C. C., Okonko, I., & Ogbonna, B. C. (2024). Tracking sustainability compliance of buildings in rapidly urbanizing Southeastern Nigeria. Sustinere: Journal of Environment and Sustainability, 8(2), 193–213. https://doi.org/10.22515/sustinere.jes.v8i2.394
Pao, S.-L., Wu, S.-Y., Liang, J.-M., Huang, I.-J., Guo, L.-Y., & Wu, W.-L. (2022). A physiological-signal-based thermal sensation model for indoor environment thermal comfort evaluation. International Journal of Environmental Research and Public Health, 19(12), 7292. https://doi.org/10.3390/ijerph19127292
Park, J.-H. (2011). Mold exposure and respiratory health in damp indoor environments. Frontiers in Bioscience-Elite, 3(2), 757–771. https://doi.org/10.2741/E284
Rahman, N. M. A., Haw, L. C., & Fazlizan, A. (2021). A literature review of naturally ventilated public hospital wards in tropical climate countries for thermal comfort and energy saving improvements. Energies, 14(2), 435. https://doi.org/10.3390/en14020435
Sánchez-García, D., Canivell, J., Pulido-Arcas, J. A., Guevara-García, F. J., & Rubio-Bellido, C. (2018). Adaptive comfort models applied to existing dwellings in Mediterranean climate considering global warming. Sustainability, 10(10), 3507. https://doi.org/10.3390/su10103507
Sari, R. M., Koerniawan, M., & Harimi, D. J. (2013). Adaptive thermal comfort in the tropic: A case study of the Aceh Tsunami Museum. Aceh International Journal of Science and Technology, 2(3), 99–107. https://doi.org/10.13170/aijst.2.3.1008
Seppanen, O. A., & Fisk, W. J. (2004). Summary of human responses to ventilation. Indoor Air, 14(Suppl 7), 102–118. https://doi.org/10.1111/j.1600-0668.2004.00279.x
Sujatmiko, B. (2009). Studi kenyamanan termal adaptif pada hunian berventilasi alami di Indonesia. Tesis. Bandung: Institut Teknologi Bandung.
Suwartha, N., & Sari, R. F. (2013). Evaluating UI GreenMetric as a tool to support green universities development: assessment of the year 2011 ranking. Journal of Cleaner Production, 61, 46–53. https://doi.org/10.1016/j.jclepro.2013.02.034
Telkom University. (2024). Green Campus Telkom University: pioneer of environmental preservation. https://greencampus.telkomuniversity.ac.id
Times Higher Education. (2021). THE Impact Rankings methodology. Times Higher Education. https://www.timeshighereducation.com
UI GreenMetric. (2022). Telkom University — partner university profile and overall rankings 2020. https://greenmetric.ui.ac.id/profile/university/telkomuniversity.ac.id
Universitas Indonesia. (2024). UI GreenMetric World University Rankings: Guideline. https://greenmetric.ui.ac.id
Yau, Y. H., & Chew, B. T. (2014). A review on predicted mean vote and adaptive thermal comfort models. Building Services Engineering Research and Technology, 35(1), 23–35. https://doi.org/10.1177/0143624412465200
Zhang, F., & Ryu, Y. (2021). Simulation study on indoor air distribution and indoor humidity distribution of three ventilation patterns using computational fluid dynamics. Sustainability, 13(7), 3630. https://doi.org/10.3390/su13073630